What is UL 300 fire suppression system?

In essence, UL 300 helps restaurants reduce their risk of kitchen fires by ensuring that their cooking equipment and kitchen setup minimize the collection of grease in ductwork and in the air.

What is ANSUL fire suppression system?

The R-102 Fire Suppression System incorporates a flexible design with an extremely effective ANSULEX Low pH Liquid Agent. ANSULEX quickly knocks down flames and cools hot surfaces, while generating a tough vapor securing blanket that helps prevent re-flash.

How much does an ANSUL system cost?

The Ansul R-102 uses a low pH liquid agent and is designed for a variety of appliances. It also detects fires in ventilating equipment, including hoods, ducts, and grease extractors. Costs range from around $3,000 to around $5,500.

What is the purpose of the ANSUL system?

An ANSUL system is a sophisticated method of extinguishing fires. A fire extinguisher or an ANSUL system applies an agent that either displaces the oxygen in its surrounding or cools the burning fuel to smother fires effectively.

Why should you upgrade to UL 300?

UL 300 keeps your people and property safer. Compared with a fire in an older appliance that used animal fat, it takes as much as six times the amount of fire-suppressing agent to bring a fire under control in an energy-efficient fryer using vegetable.

Is an Ansul system wet or dry?

Ansul R102 Wet Chemical Fire Suppression Systems, fire suppression system, dry chemical fire suppression.

Do I need a fire suppression system in my restaurant?

Wet Chemical Fire Suppression Systems in Commercial Kitchens. The NFPA 96 requires automated fire suppression equipment for all grease removal devices, hood exhaust plenums, and exhaust duct systems in a commercial kitchen, as well as any cooking equipment that produces grease-laden vapors.

How often does an Ansul system need to be inspected?

once every six months
A complete inspection of your Ansul kitchen hood fire suppression system should happen regularly — at least once every six months, according to NFPA 96. To complete the inspection, you’ll need to first coordinate maintenance with a factory authorized, trained service technician.

How much does a dry chemical fire suppression system cost?

In general, here are the costs you can expect: $1 to $2 per sprinklered square foot for new construction projects. $2 to $7 per sprinklered square foot for retrofitting existing homes and businesses. $2 to $4 per sprinklered square foot for retrofitting high-rise buildings.

Is UL 300 wet or dry?

UL-300 systems use wet chemicals which serve two purposes: 1.) To smother the fire, similar to the way dry chemicals did; and 2.) To cool the liquids so they don’t reignite, something dry chemicals systems couldn’t do.

What are fire suppression systems and how do they work?

Stopping fires from spreading means that you’ll reduce the damage done to your building as a whole.

  • When you suppress fires,you’re keeping yourself and your staff safe.
  • When you have the right suppression system in place,you’ll find that it’ll be much easier on your insurance premiums.
  • How do you install a fire suppression system?

    Carbon Dioxide Fire Suppression Systems. One of the most popular types of fire suppression systems is the carbon dioxide system.

  • Clean Agent Fire Suppression Systems. Like the name suggests,a clean agent fire suppression system is extremely eco-friendly.
  • Restaurant Fire Suppression Systems.
  • Industrial Fire Suppression Systems.
  • How long does an Ansul Fire system service take?

    How long does an Ansul fire system service take? With an Aura Fire Safety (AFS) Specialist we will work with you to keep up regular maintenance and testing for your Ansul system. Typically a semi-annual test will take roughly 30 minutes to 1 hour depending on the size of the hood and the number of appliances. This is time well spent.

    How to install a fire suppression system?

    The wet-fire protecting system updated the EFSR (Early Suppression, Fast Response) sprinkler heads that are fast response sprinkler and quick responding, EFSR system are designed to suppress fire through the discharge of a large volume of water directly at the fire to reduce the heat release rate.